Ambulance Uses DC 12V Surgical Suction Pump

Ambulance Uses DC 12V Surgical Suction Pump

Ambulance Uses DC 12V Surgical Suction Pump

ANGELBISS Modern Immediate Plug-in CZPT System & Double anti-overflow defense technique. Operate 3 several hours without AC power

Characteristics:

  1. Rechargeable DC 12V
  2. Ambulance automobile use DC 12V
  3. Quickly recharge in 90 minutes, Steady operate a hundred and eighty minutes (3 hrs)
  4. Exceptional CZPTium batteries
  5. Double anti-overflow defense technique
  6. Direct Plug-in CZPT Technique, only one particular drive to consider out bottle
  7. 1400ml capability suction bottle
  8. Innovative filter technological innovation which prevents penetration of micro organisms and secretion into the gadget
  9. Only a single inlet for suction hose, steer clear of deceptive of air inlet and outlet
  10. Easy thoroughly clean & sterilize & user-helpful functions

CZPT Technical specs
 

Program Map Features AverLast 18B
Pump Driving Technique Max. Air Flow 18L/min
Max. Vacuum Pressure .07Mpa
Function Manner Constantly Run
CZPT Technique Max. Jar capacity 1400ml
Overflow CZPT Double Security CZPT
Progressive CZPT Water-resistant
Reusable
Inlet Cover 1 only, and no want outlet
CZPTtrical System Pump Electrical power Consumption DC 12V, a hundred thirty W
Adapter Electrical power AC 220V Input, DC 12V Output
CZPTium CZPTeries (If new) one set, DC 12V
Full cost time about 1.5 hour
Assistance use time three hours
Ambulance Car Adapter DC 12V
Automobile Power off two several hours
Power Fuse one. A -φ5×20mm
Sounds Stage <50dB(A)
Operate Program
 
Vacuum Gauge Assortment .00Mpa ~ .1Mpa
(0psi ~14psi)
Vacuum Control Range .02Mpa ~ .07Mpa
Suction Hose Hold Groove A single, at the left
Wall mounted Dangle Suggestion Two, at the back
Concealed Rotatable Handle Indeed, at the best
four Safety Technique Floating method Very first level stop overflow
CZPT strategy Next level stop overflow
Overheated CZPT Indeed
CZPTery complete cost Complete cost will automobile isolate with AC electrical power
CZPT Specifics CZPT Body Measurement 283x195x273mm
CZPT Carton Dimension 415x360x300mm for two models
Net Excess weight for every Unit four.two kg
CZPT Gross Weight per Carton nine.8 kg
Working
Issue
Operating Temperature 41ºF to 104ºF (5ºC to 40ºC)
Running Humidity ten% to ninety% RH
Functioning Atmospheric Strain 700-1060hpa
Storage Temperature -4ºF to 131ºF(-20ºC to 55ºC)
Storage Humidity ten to ninety five% RH

Ambulance Uses DC 12V Surgical Suction Pump